Application of China factory Thermal Resistance RTD WZP2-231 in Power Plants

Date:2023/3/6 9:51:15 Visits: Author:Dongfang YOYIK Engineering Co; Ltd,

 Application of China factory Thermal Resistance RTD WZP2-231 in Power Plants

 
Thermal Resistance RTD WZP2-231 is widely used in thermal power plants to measure the temperature of various equipment and systems. The following are some of the main application areas:
1. Steam turbine: thermal resistance is usually used to measure the temperature of various parts of the steam turbine, such as the temperature of the inlet of the high pressure cylinder and medium pressure cylinder, the temperature of the oil in the oil system, etc. These temperature data can be used to determine whether the equipment is working properly and whether maintenance and maintenance are required.
2. Boiler: Thermal resistance is used to measure the temperature of various parts of the boiler, such as inside the steam drum, superheater, reheater, air preheater, etc. These temperature data are very important to ensure the safe operation of the boiler, and can be used to judge whether the equipment is normal, control the combustion process and adjust the combustion parameters.
3. Flue gas emission: RTDs are also used to measure the temperature of the flue gas to ensure that the flue gas emission of the boiler meets environmental protection requirements.
4. Other equipment: Thermal Resistance RTD WZP2-231 is also used to measure the temperature of steam generators, air compressors, water pumps, cooling towers, heat exchangers and other equipment.
In general, thermal resistance is widely used in thermal power plants, which can provide important temperature data, ensure the normal operation of equipment, and ensure the safety and stability of the production process. 
 
Application of China factory Thermal Resistance RTD WZP2-231 in Power Plants
Pressure switch B420B XFSNH
Lubricating oil pressure switch BH-038013-03
Vacuum Low Voltage Switch BH-038029-038
EDI Module CP-3600S
Pressure gauge of filter pressure reducing valve G46-10-02
Pressure gauge HM100-250-R-M20×1.5-BF
Travel switch ITS-100
Pressure switch J120K-540\50~1740Pa
Liquid level transmitter LS15 S3F560A
Liquid level transmitter LS20700 P10T1AK
Electrode RDJ-2000
Pressure transmitter STG94L-E1G-00000-HC
Thermocouple WRNK-231TZ/K/550/5/0¡«1200¡æ/M20*1.5
Armoured Wear Resistant Thermocouple WRNK2-430NM/DN50/L=1150*1000*650
Bearing Outlet Temperature Measuring Element WSSP-481
Bearing Bush Temperature Measuring Element WZPK2-220
Thermal resistance WZPK2-231-G1/PT100/300/6/0¡«250¡æ
Thermal resistance WZPK-24\-200~450¡æ\120\φ6\Pt100
LOAD CELL XK3102-S
Temperature Controller XMT604B
Positioner YT3300RDN5201S
Travel switch ZV7H236-11Z
Guide blade opening DYK-II-1013
DFYLSYC-2023-03-06-A
Thermal,Resistance,RTD